Address: Date:
DESCRIPTION OF PROPERTY:
Type: freestandingsemi-detachedattached both sidessingle storeytwo storeysplit levelhome unitvillatownhouseother
Walls: double brickbrick veneerweatherboardfibroaluminiumVinylconcrete blocksandstoneother
Roof: tilesmetalslateasbestos cementother
Floor: timberconcrete
INSIDE THE HOUSE:
Termites: ActiveNon-Active Borers: AnobiumLyctus
Location of infestation:
Amount of damage: N/AMinormoderatesevere.
Is furniture concealing access or visibility: YesNo
Are there wall linings concealing timber wall framing: YesNo
Concealed timber floor framing to first floor level or between levels: YesNo
Are there stairs: YesNo.
Access under stairs: N/AYesNo
Are there floorcoverings: YesNo
Are there built-ins: YesNo
Full of personal effects: N/AYesNo
Are there fireplaces: YesNo
How many: N/A
Excess furniture and personal effects abutting walls & skirtings: YesNo
ROOF CAVITY: ManholeTrap doorLoft ladderother
Termites: ActiveNon-ActiveNil Borers: AnobiumLyctusNil
Amount of damage: Minormoderatesevere.
Separate cavity: N/AYesNo
Is there sarking: NilAluminium foilBituminous paperPlastic
Is there other insulation: NilBattsBlown-inLoose fibreFoamother
Is there DustDirtDebrisStored goodsFlooringNilN/A
Are there sections of the timber roof frame not exposed to view: YesNoN/ATight & inaccessible trussesSloping roofElectric cablesPlumbing pipesHot water tankOther
Air conditioning YesNoN/A
Is there delignification: YesNoN/A
Location: N/ABattensRafters
Severity: MinorModerateSevere
SUBFLOOR Concrete floorOpen foundationsFloor trapFoundation wallother
Location of infestation: BearersJoistsFloorboardsLoose timber
Is there a separate subfloor: N/AYesNo
Are there areas that could not be inspected: N/AFloor close to groundStored goodFloodedPlumbing pipesElectric cablesOther
Are some floors concrete: YesNo
If yes, state where: BathroomLaundryKitchenPatioRear extensionFrontOther
Damaged timber due to wood rot especially below bathrooms YesNo
Extent of damage: N/AMinorModerateSevere
Leaks from wet areas: YesNo
Location: BathroomEn suiteKitchenLaundry
Loose timber on ground: YesNo
Formwork : YesNo
Are there antcaps:YesNo
Condition of antcaps:N/ASatisfactoryRustedPoor condition
Are there personal effects in subfloor:YesNo
Is there air conditioning:YesNo
Fungi growth:YesNo
Is the soil damp:YesNo
Are there adequate vents in exterior walls:YesNo
Ventilation:Very poorPoorAdequate
Are there vents:YesNo
Weepholes:YesNo
Is there access under fireplaces:N/AYesNo
EXTERIOR YARD:
Garden sleepers on ground YesNo
Wood rot: N/AMinorModerateSevere
Logs on the ground: YesNo
Are there timber retaining walls: YesNo
Are there garden bedsconcreted areaspaved areasNil up against exterior walls
If yes, are they above internal floor orabove the level of the vents :N/AYesNo
Are there foliageshrubstreesNil in contact with exterior walls
Are trees overhanging roof: YesNo
Is the edge of the concrete slab exposed to view: N/AYesNo
Is the fall of land away from the house: YesNo
Wood rot in external timbers: NilMinorModerateSevere
Is there BushlandwaterwaysNil close by
FENCING
What sort of fencing is there: NilTimberTreated pineBrickMetalConcrete blockAsbestosSandstoneStoneFibre cement
Any termites in fences: NoActiveNon active
Damage: N/AMinorModerateSevere
Any borers in fences: NoLyctusAnobium
Any woodrot in fences: N/AYesNo
Are fences concealed by vines or shrubs: N/AYesNo
Are personal effects concealing any section of house: YesNo
Are building materials concealing any section of house: YesNo
Any fences or retaining walls concrete block: YesNo
TREES & STUMPS
Are there any trees orstumps on the property:No
Any termites:NoActiveNon-active
Are there vines in trees restricting inspection N/AYesNo
GARAGE/CARPORT
NilGaragesCarportsFreestandingAttachedUnder
Termites:NilActiveNon-active
Damage:NilMinorModerateSevere
Location of damage:N/AFloorWallsRoof
Borers:NilLyctusAnobium
Termites:NilActiveNon active
Damage:N/AMinorModerateSevere
Walls:TimberMetalBrickFibroAluminiumVinylConcrete blockOther
Floor:DirtTimberConcrete.
Roof:TilesMetalAsbestosPVCOther
Is there a ceiling cavity:YesNo
If yes, is there access to ceiling cavity: N/AYesNo
Are personal effects concealing interior or exterior of structure:YesNo
Is the edge of the concrete slab exposed to view:YesNoNo concrete
Sheds:
Termites:NilActiveNon-active Damage:NilMinorModerateSevere Location of damage:N/AFloorWallsRoof
Borers:NilLyctusAnobium Termites:NilActiveNon active
BalconiesPergolasDecksNil
Construction of floor:TimberConcreteDirt
Wood Rot:YesNo
Location of Wood Rot:N/AFloorWallsRoof
Any sections that could not be inspected:YesNo
If yes, state areas:
Any timber posts in ground:YesNo
additional access required to any section of the property: YesNo
Previous Termite treatment: YesNo
Treatment recommended: YesNo